久久亚洲日韩av一区二区三区-亚洲成无码人在线观看-日韩亚洲欧美久久久www综合-亚洲综合熟女久久久30p-av怡红院一区二区三区

     
  中文版 English
 
Hot news:
  Products
IEC Test Finger Probe
IPX1-IPX9K Waterproof Test Equipment
Electrical Appliance Testing Equipment
Environmental Test Chamber
Battery test equipment
Textile Test Equipment
Mechanical testing machine
Plug and socket testing equipment
test package
Laser Power Senser Measurement
Soil Sensor
Hot Product
IPX1 IPX2 Drip Waterproof Test...
UL1439 Sharp Edge Tester
BND-TPK05 IEC 60529 Test Probe...
IEC62368 test probe kit BND-TP...
IEC 61032 Standard Test Probe ...
IEC60320 EN60320 Appliances co...
UL 498 Standard Plugs and Rece...
IPX1 to IPX4 Drip rain test an...
Vertical horizontal vibration ...
IP5X IP6X Sand and dust proof ...
climate constant temperature a...
IPX1 to IPX9 waterproof testin...
 
 
Products
IEC61347 EN61347-1-Figure D.1 Annex D heating test enclosure heating test box
Name:IEC61347 EN61347-1-Figure D.1 Annex D heating test enclosure heating test box
Type:BND-WSX
Manufacturer:IEC61347 EN61347-1-Figure D.1 Annex D heating test enclosure heating test box,Temperature rise test
Product Description:

IEC61347 EN61347-1-Figure D.1 Annex D heating test enclosure heating test box


D.1 Test enclosure

The heating tests are made in an enclosure in which the temperature of the ambient air is

maintained as specified (see Figure D.1). The entire test enclosure shall be constructed of

heat resistant material 25 mm thick. The test compartment of this enclosure shall have

internal dimensions of 610 mm × 610 mm × 610 mm. The floor of the test compartment shall

measure 560 mm × 560 mm, permitting an air space of 25 mm all around the platform for

circulation of the heated air. A 75 mm heater compartment shall be provided below the floor of

the test area for the heating elements. One side of the test compartment may be removable,

but shall be so constructed that it can be securely fastened to the remainder of the enclosure.

One of the sides shall have a 150 mm square opening located centrally at the bottom edge of

the test compartment, and the enclosure so constructed that the only possibility of air

circulation will be through this opening. The opening shall be covered by an aluminium shield

as shown in Figure D.1.


D.2 Heating of enclosure

The heat source used for the test enclosure described above shall consist of four 300 W strip

heaters having approximate heating surface dimensions of 40 mm × 300 mm. These elements

shall be connected in parallel to the supply source. The elements shall be mounted in the

75 mm heater compartment midway between the test compartment floor and the base, and so

arranged that they form a square with the outside edge of each element 65 mm from the adjacent

inside wall of the enclosure. The elements shall be controlled by a suitable thermostat.


D.3 Lamp control gear operating conditions

During the test, the frequency of the supply circuit shall be the rated frequency of the lamp

controlgear, and the voltage of the supply circuit shall be the rated supply voltage of the lamp

controlgear. During the test, the temperature in the enclosure shall be maintained at 40(±5) °C;

prior to the test, the lamp controlgear (not energized) shall be placed in the chamber for a

sufficient interval of time to allow all parts to attain the temperature of the air therein. If the

temperature in the chamber at the end of the test differs from that at the beginning of the test,

this temperature differential shall be taken into account in determining the temperature rise of

the components of the lamp control gear. The lamp control gear shall supply the number and

size of lamps for which it is intended. Lamps shall be placed outside the enclosure.


D.4 Lamp control gear position in the enclosure

During the test, the lamp controlgear shall be in its normal operating position supported

75 mm above the floor of the test compartment by two 75 mm wooden blocks, and shall be

centrally located with respect to the sides of the enclosure. Electrical connections may be

brought out of the enclosure through the 150 mm square opening illustrated in Figure D.1.

During the test, the enclosure shall be so located that the shielded opening is not exposed to

draughts or rapid air currents.



D.5 Temperature measurements

The average ambient temperature in the enclosure is assumed to be the average air

temperature at positions not less than 76 mm from the nearest wall and on a level with the

centre of the lamp control gear.

The temperature is usually measured by a glass thermometer. An alternative sensor is a

thermocouple or 'thermistor' attached to a small metal vane shielded against radiation.

Temperatures on the case are usually measured by means of thermocouples. A temperature

is considered to be constant when three successive readings, taken at intervals of 10 % of the

previously elapsed duration of the test (but not less than 5 min intervals), indicate no change.


 
Home  |  Products  |  News  |  About us  |  Feedback  |  Contact us  |  
Copyright © 2008-2015 Hong Kong Bonad Technology Limited | Shenzhen Bonad Instrument Co., LTD. All Rights Reserved.
 
    Add:C505, Hongdu Building,Bao\\\'an45 district,Shenzhen,518101,Guangdong Province,China    Tel:+86-13380391156    Fax:0755-23721200    Email:Alice@szbonad.com
 
主站蜘蛛池模板: 亚洲国产一区二区三区四区电影网| 天堂资源最新在线| 亚洲七七久久桃花影院| 中文日产幕无线码6区收藏| 亚洲精品色在线网站| 亚洲人亚洲人成电影网站色| 青草青草久热精品视频国产4| 一本久道久久综合狠狠老| 女人18毛片水最多| 777午夜精品免费观看| 久久亚洲人成网站| 四虎影视久久久免费| 少妇爆乳无码专区网站| 亚洲人成影院在线无码按摩店| 午夜私人成年影院| 扒开?让我???蜜桃视频| 美女av一区二区三区| 在线播放亚洲第一字幕| 亚洲欧美精品aaaaaa片| 亚洲色无码中文字幕在线| 熟女少妇丰满一区二区| 18禁免费观看网站| 亚洲图片小说激情综合| 人妻奶水人妻系列| ,粉嫩小泬BBBB免费看| 99国产精品白浆在线观看免费| 国产成人高清在线重口视频| 黄网站欧美内射| 亚洲综合无码明星蕉在线视频| 麻豆精产一二三产区| 国产一区二区无码蜜芽精品| 歪歪爽蜜臀av久久精品人人| 精品亚洲国产成人| 国产精品熟女人妻 | 久久久网站| 欧美成人www免费全部网站| 国产av无码专区亚洲a√| 夜夜爽一区二区三区精品| 国产一区二区四区在线观看| 国产末成年女av片一区二区| 久久久国产一区二区三区四区小说 |